TRUMETER 7932 Preset counter and timer with one relay output
223,48 € plus VAT.
6 Stück auf Lager
Description
TRUMETER 7932 Preset counter and timer with one relay output
This versatile up and down counting preset counter and timer with prescaler has a variety of innovative and attractive features. New ideas in development and adherence to the highest standards in production enable piece counting and time counting in one device. The count inputs are optically isolated and can be configured as sink (NPN) or source (PNP). The count value is shown on the main display and the preset value on the secondary display. Reset can be remote, manual or automatic, with the option of manual override.
Features
- Supply voltage 85–265 V AC or 10–26 V DC
- Auxiliary output 12 V DC
- Programmable for time or pulse counter
- Prefix value 1-999999
- adjustable to a maximum of 3 decimal places
- Scaling factor multiplication 0.00250–9.99999, division 1–99999
- Counting input NPN, PNP
- Fast counting input 10-30 V DC, max. 10 kHz
- Slow counting input 12-240 V AC/DC, max. 30 Hz
- Manual, external or automatic reset
- 1 output relay 5 A as normally closed or normally open contact
- EEPROM data storage
- Backlight
- Dimensions (WxHxD): 48 x 48 x 93 mm
- CE, UL and cUL tested
FAQ
7922 and 7932 use an EEPROM to back up the programming and count values. This is done by monitoring the meter's internal power supply.
If the external supply voltage is switched off, the internal voltage drops accordingly. This is registered by a special circuit and the backup mechanisms are activated so that all relevant data is saved in the non-volatile memory. In addition, a so-called „checksum“ is generated, which is also stored in the memory.
When the external power is switched back on, the processor reads the data from the memory, generates a checksum and compares it with the stored checksum. If the new checksum differs from the previously stored one, the processor interprets this as an error and assumes that there is a data error. This results in the message „ERR CH“, which signals a data error.
This error can be caused by a defect in the processor, in the EEPROM, or by external voltage spikes. If the error is caused by external voltage spikes, it can be avoided by using suitable filters. A “power-up reset” is required to eliminate this error.
- Switch off the power supply.
- Press and hold the PROG button and digit 5 button simultaneously.
- Switch the power supply back on while holding down the buttons. Hold the buttons down for approx. 15 seconds until 7922/7932 appears on the display.
- The EEPROM memory has now been reset to its default values and the meter must be reprogrammed.
Additional information
| Supply voltage | 230 V AC |
|---|---|
| Switch output | Relay |